12 research outputs found

    Toward Speed-of-Sound Anisotropy Quantification in Muscle With Pulse-Echo Ultrasound

    Full text link
    The velocity of ultrasound longitudinal waves (speed of sound) is emerging as a valuable biomarker for a wide range of diseases, including musculoskeletal disorders. Muscles are fiber-rich tissues that exhibit anisotropic behavior, meaning that velocities vary with the wave-propagation direction. Therefore, quantifying anisotropy is essential to improve velocity estimates while providing a new metric related to muscle composition and architecture. For the first time, this work presents a method to estimate speed-of-sound anisotropy in transversely isotropic tissues using pulse-echo ultrasound. We assume elliptical anisotropy and consider an experimental setup with a flat reflector parallel to the linear probe, with the muscle in between. This setup allows us to measure first-arrival reflection traveltimes using multistatic operation. Unknown muscle parameters are the orientation angle of the anisotropy symmetry axis and the velocities along and across this axis. We derive analytical expressions for the nonlinear relationship between traveltimes and anisotropy parameters, including reflector inclinations. These equations are exact for homogeneous media and are useful to estimate the effective average anisotropy in muscles. To analyze the structure of this forward problem, we formulate the inversion statistically using the Bayesian framework. We demonstrate that anisotropy parameters can be uniquely constrained by combining traveltimes from different reflector inclinations. Numerical results from wide-ranging acquisition and anisotropy properties show that uncertainties in velocity estimates are substantially lower than expected velocity differences in the muscle. Thus, our approach could provide meaningful muscle anisotropy estimates in future clinical applications

    Pulse-echo speed-of-sound imaging using convex probes.

    Get PDF
    Computed ultrasound tomography in echo mode (CUTE) is a new ultrasound (US)-based medical imaging modality with promise for diagnosing various types of disease based on the tissue's speed of sound (SoS). It is developed for conventional pulse-echo US using handheld probes and can thus be implemented in state-of-the-art medical US systems. One promising application is the quantification of the liver fat fraction in fatty liver disease. So far, CUTE was using linear array probes where the imaging depth is comparable to the aperture size. For liver imaging, however, convex probes are preferred since they provide a larger penetration depth and a wider view angle allowing to capture a large area of the liver. With the goal of liver imaging in mind, we adapt CUTE to convex probes, with a special focus on discussing strategies that make use of the convex geometry in order to make our implementation computationally efficient. We then demonstrate in an abdominal imaging phantom that accurate quantitative SoS using convex probes is feasible, in spite of the smaller aperture size in relation to the image area compared to linear arrays. A preliminary in vivo result of liver imaging confirms this outcome, but also indicates that deep quantitative imaging in the real liver can be more challenging, probably due to the increased complexity of the tissue compared to phantoms

    Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers

    Full text link
    OBJECTIVES: Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. METHODS: Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. RESULTS: SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. CONCLUSION: Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good

    Impact of Breathing Phase, Liver Segment, and Prandial State on Ultrasound Shear Wave Speed, Shear Wave Dispersion, and Attenuation Imaging of the Liver in Healthy Volunteers.

    Get PDF
    OBJECTIVES Measurement location and patient state can impact noninvasive liver assessment and change clinical staging in ultrasound examinations. Research into differences exists for Shear Wave Speed (SWS) and Attenuation Imaging (ATI), but not for Shear Wave Dispersion (SWD). The aim of this study is to assess the effect of breathing phase, liver lobe, and prandial state on SWS, SWD, and ATI ultrasound measurements. METHODS Two experienced examiners performed SWS, SWD, and ATI measurements in 20 healthy volunteers using a Canon Aplio i800 system. Measurements were taken in the recommended condition (right lobe, following expiration, fasting state), as well as (a) following inspiration, (b) in the left lobe, and (c) in a nonfasting state. RESULTS SWS and SWD measurements were strongly correlated (r = 0.805, p < 0.001). Mean SWS was 1.34 ± 0.13 m/s in the recommended measurement position and did not change significantly under any condition. Mean SWD was 10.81 ± 2.05 m/s/kHz in the standard condition and significantly increased to 12.18 ± 1.41 m/s/kHz in the left lobe. Individual SWD measurements in the left lobe also had the highest average coefficient of variation (19.68%). No significant differences were found for ATI. CONCLUSION Breathing and prandial state did not significantly affect SWS, SWD, and ATI values. SWS and SWD measurements were strongly correlated. SWD measurements in the left lobe showed a higher individual measurement variability. Interobserver agreement was moderate to good

    Tomography across scales: Knowledge transfer from seismology to imaging breast tissue with ultrasound

    No full text
    Wave propagation is extensively used to understand the internal structure of media that are not accessible to direct observations. Seismology and medical ultrasound imaging are good examples of this. The former uses observations of seismic waves at the Earth's surface to increase our knowledge about its interior. This is crucial, for instance, to improve our understanding about the Earth's dynamics and evolution. Medical ultrasound, on the other hand, uses observations of acoustic waves, emitted and recorded at the surface of human bodies, to visualize internal body structures. This has become an essential screening tool, useful for diagnostic examination. This thesis presents an interdisciplinary work between seismology and medical ultrasound. In particular, we focus on transferring knowledge from seismic tomography to Ultrasound Computer Tomography (USCT), an emerging technology that holds great potential for early-stage breast cancer diagnosis. Here, the human breast is surrounded by transducers that collect transmitted and reflected ultrasound signals. This information is then used to obtain 3D quantitative images of acoustic tissue properties, which enable non-invasive tissue characterization and improve the specificity of standard imaging modalities. Current challenges in USCT mostly consist in providing a diagnostic tool with high accuracy (comparable to magnetic resonance imaging) and affordable computational and acquisition cost for clinical practice, the target being a maximum time of 15 minutes per patient. Despite the vastly different scale, seismic and medical ultrasound tomography share fundamental similarities that allow us to address these challenges from the stand point of the seismologist. We first introduce finite-frequency traveltime tomography to medical ultrasound. In addition to being computationally tractable for 3D imaging at high frequencies, the method has two main advantages: (1) It correctly accounts for the frequency dependence and volumetric sensitivity of traveltime measurements, which are related to off-ray-path scattering and diffraction. (2) It naturally enables out-of-plane imaging and the construction of 3D images from 2D slice-by-slice acquisition systems. Our method rests on the availability of calibration data measured in water, used to linearize the forward problem and to provide analytical expressions of cross-correlation traveltime sensitivity. We present a memory-efficient implementation suitable for arbitrarily large-scale domains, and we discuss its extension to amplitude tomography. To adapt existing acquisition systems to new imaging techniques, we then introduce optimal experimental design methods. These provide a systematic and quantitative framework to (1) evaluate the quality of different designs in terms of uncertainties in the estimated tissue parameters and (2) optimize the configuration with respect to predefined design parameters, for example the position of transducers on the scanning device. Our first application presents a cost-effective 3D configuration of transducers optimized for transmission tomography. This is useful to analyze appropriate quality measures for USCT experiments and explore computationally tractable optimization approaches. The multi-modality capability of USCT, however, requires careful designs that simultaneously provide accurate images for both transmission (e.g., velocity) and reflection (reflectivity) information. We therefore extend the formulation to jointly optimize the experiment for transmission and reflection data. Here we focus on image reconstruction methods with linear(ized) observable-parameter relationship, for which quality measures are analytically given and independent of breast properties. This is crucial for optimizing USCT devices prior to any data acquisition. Methods investigated within this thesis are validated using experimental data. These contributions represent innovative solutions for USCT and ultimately serve to foster the knowledge and technology transfer between seismology and medical imaging, which may benefit imaging methods on all scales

    Quantifying gender gaps in seismology authorship

    No full text
    According to 2018 demographic data of the American Geophysical Union Fall Meeting, seismology is among the geoscience ?elds with the lowest representation of women. To understand whether this reflects seismology more generally, we investigate women's authorship of peer-reviewed publications, a key factor in career advancement. Building upon open-source tools for web-scraping, we create a database of bibliographic information for seismological articles published in 14 international journals from 2010 to 2020. We use the probabilities of author names being either male- or female-gendered to analyse the representation of women authors in terms of author position and subsequently per journal, year, and publication productivity. The results indicate that (1) the overall probability of the first (last) author being female is 0.28 (0.19); (2) with the calculated rate of increase from 2010 to 2020, equal probabilities of female and male authorship would be reached towards the end of the century; (3) compared to the overall probability of male authorship (0.76), single-authored papers in our database are disproportionately published by male authors (with a probability of 0.83); (4) female representation decreases among highly productive authors; and (5) rather than being random, the composition of authorship appears to be influenced by gender - firstly, all-male author teams are more common than what would be expected if teams were composed randomly; secondly, the probability that first or co-authors are female increases when the last author is female, but first female authors have a low probability of working with female co-authors.ISSN:1869-9510ISSN:1869-952

    Speed of sound and shear wave speed for calf soft tissue composition and nonlinearity assessment

    Get PDF
    Background The purpose of this study was threefold: (I) to study the correlation of speed-of-sound (SoS) and shear-wave-speed (SWS) ultrasound (US) in the gastrocnemius muscle, (II) to use reproducible tissue compression to characterize tissue nonlinearity effects, and (III) to compare the potential of SoS and SWS for tissue composition assessment. Methods Twenty gastrocnemius muscles of 10 healthy young subjects (age range, 23-34 years, two females and eight males) were prospectively examined with both clinical SWS (GE Logiq E9, in m/s) and a prototype system that measures SoS (in m/s). A reflector was positioned opposite the US probe as a timing reference for SoS, with the muscle in between. Reproducible tissue compression was applied by reducing probe-reflector distance in 5 mm steps. The Ogden hyperelastic model and the acoustoelastic theory were used to characterize SoS and SWS variations with tissue compression and extract novel metrics related to tissue nonlinearity. The body fat percentage (BF%) of the subjects was estimated using bioelectrical impedance analysis. Results A weak negative correlation was observed between SWS and SoS (r=-0.28, P=0.002). SWS showed an increasing trend with increasing tissue compression (P=0.10) while SoS values decayed nonlinearly (P<0.001). The acoustoelastic modeling showed a weak correlation for SWS (r=-0.36, P<0.001) but a very strong correlation for SoS (r=0.86, P<0.001), which was used to extract the SoS acoustoelastic parameter. SWS showed higher variability between both calves [intraclass correlation coefficient (ICC) =0.62, P=0.08] than SoS (ICC =0.91, P<0.001). Correlations with BF% were strong and positive for SWS (r=0.60, P<0.001), moderate and negative for SoS (r=-0.43, P=0.05), and moderate positive for SoS acoustoelastic parameter (r=0.48, P=0.03). Conclusions SWS and SoS provide independent information about tissue elastic properties. SWS correlated stronger with BF% than SoS, but measurements were less reliable. SoS enabled the extraction of novel metrics related to tissue nonlinearity with potential complementary information

    Toward Speed-of-Sound Anisotropy Quantification in Muscle With Pulse-Echo Ultrasound

    No full text
    The velocity of ultrasound longitudinal waves (speed of sound) is emerging as a valuable biomarker for a wide range of diseases, including musculoskeletal disorders. Muscles are fiber-rich tissues that exhibit anisotropic behavior, meaning that velocities vary with the wave-propagation direction. Therefore, quantifying anisotropy is essential to improve velocity estimates while providing a new metric related to muscle composition and architecture. For the first time, this work presents a method to estimate speed-of-sound anisotropy in transversely isotropic tissues using pulse-echo ultrasound. We assume elliptical anisotropy and consider an experimental setup with a flat reflector parallel to the linear probe, with the muscle in between. This setup allows us to measure first-arrival reflection traveltimes using multistatic operation. Unknown muscle parameters are the orientation angle of the anisotropy symmetry axis and the velocities along and across this axis. We derive analytical expressions for the nonlinear relationship between traveltimes and anisotropy parameters, including reflector inclinations. These equations are exact for homogeneous media and are useful to estimate the effective average anisotropy in muscles. To analyze the structure of this forward problem, we formulate the inversion statistically using the Bayesian framework. We demonstrate that anisotropy parameters can be uniquely constrained by combining traveltimes from different reflector inclinations. Numerical results from wide-ranging acquisition and anisotropy properties show that uncertainties in velocity estimates are substantially lower than expected velocity differences in the muscle. Thus, our approach could provide meaningful muscle anisotropy estimates in future clinical applications.ISSN:0885-3010ISSN:1525-895

    Excluding Echo Shift Noise in Real-Time Pulse-Echo Speed-of-Sound Imaging

    Get PDF
    Computed ultrasound tomography in echo mode (CUTE) allows real-time imaging of the tissue speed of sound (SoS) using handheld ultrasound. The SoS is retrieved by inverting a forward model that relates the spatial distribution of the tissue SoS to echo shift maps detected between varying transmit and receive angles. Despite promising results, in vivo SoS maps often show artifacts due to elevated noise in echo shift maps. To minimize artifacts, we propose a technique where an individual SoS map is reconstructed for each echo shift map separately, as opposed to a single SoS map from all echo shift maps simultaneously. The final SoS map is then obtained as a weighted average over all SoS maps. Due to the partial redundancy between different angle combinations, artifacts that appear only in a subset of the individual maps can be excluded via the averaging weights. We investigate this real-time capable technique in simulations using two numerical phantoms, one with a circular inclusion and one with two layers. Our results demonstrate that the SoS maps reconstructed using the proposed technique are equivalent to the ones using simultaneous reconstruction when considering uncorrupted data but show significantly reduced artifact level for data that are corrupted by noise
    corecore